Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: surge protectionDescription: TBU ?High speed protector TBU? High-Speed Protectors98705+$2.600125+$2.407550+$2.2727100+$2.2149500+$2.17642500+$2.12825000+$2.109010000+$2.0801
-
Category: surge protectionDescription: BOURNS SA2-3600-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 4.32 kV, Axial Lead, 5 kA, 5.4 kV84135+$4.807425+$4.451350+$4.2020100+$4.0952500+$4.02392500+$3.93495000+$3.899310000+$3.8459
-
Category: surge protectionDescription: SA2Series SA2 High Voltage Gas Discharge Tube87955+$5.032825+$4.660050+$4.3990100+$4.2872500+$4.21262500+$4.11945000+$4.082210000+$4.0262
-
Category: surge protectionDescription: BOURNS SA2-5500-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 6.6 kV, Axial Lead, 5 kA, 8 kV20135+$4.826325+$4.468850+$4.2185100+$4.1113500+$4.03982500+$3.95045000+$3.914610000+$3.8610
-
Category: surge protectionDescription: BOURNS SA2-6200-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 7.44 kV, Axial Lead, 5 kA, 8 kV29735+$4.826325+$4.468850+$4.2185100+$4.1113500+$4.03982500+$3.95045000+$3.914610000+$3.8610
-
Category: surge protectionDescription: Bourns SA Series High Voltage Gas Discharge Tube # # # Transient Voltage Suppressor (Inflatable)11255+$11.901250+$11.3926200+$11.1078500+$11.03661000+$10.96542500+$10.88405000+$10.83327500+$10.7823
-
Category: surge protectionDescription: BOURNS SA2-4500-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 Series28595+$12.317850+$11.7914200+$11.4966500+$11.42291000+$11.34922500+$11.26505000+$11.21237500+$11.1597
-
Category: surge protectionDescription: SA2Series SA2 High Voltage Gas Discharge Tube99275+$4.943725+$4.577550+$4.3212100+$4.2113500+$4.13812500+$4.04655000+$4.009910000+$3.9550
-
Category: surge protectionDescription: BOURNS SA2-6300-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 7.56 kV, Axial Lead, 5 kA, 9.2 kV48685+$20.434150+$19.5608200+$19.0718500+$18.94951000+$18.82732500+$18.68765000+$18.60027500+$18.5129
-
Category: surge protectionDescription: SMD Gas Discharge Tube -2051 Series Bourns ® The 2051 series miniature gas discharge tube (GDT) is extremely compact in size (2.7 x 3.2 x 4.5 mm) and is a powerful overvoltage protection product. The 2051 series GDT is specifically designed to meet the circuit board level protection requirements of telecommunications and industrial communication equipment with space limitations, suitable for PCI cards, MDC modems, splitters, and CPE applications. In addition, the 2051 series GDT has low capacitance, making it ideal for high-speed/high bandwidth applications. ###Main features: - Small structure, low capacitance, stable performance throughout the lifecycle, high insulation resistance, UL certification # # # Applications include: - MDC/PCI modems, splitters, telecommunications CPE data communication # # # Transient voltage suppressors (inflatable)946910+$1.004450+$0.9523100+$0.9151300+$0.8928500+$0.87051000+$0.84822500+$0.81475000+$0.8072
-
Category: surge protectionDescription: BOURNS 2051-30-SM-RPLF. Gas discharge tube, 2KA, 750V, 2-pole SMD38125+$2.805325+$2.597550+$2.4520100+$2.3897500+$2.34812500+$2.29625000+$2.275410000+$2.2442
-
Category: surge protectionDescription: BOURNS 2045-12-BLF Gas Discharge Tube (GDT), 2-Electrode, 2045 series, 120 V, axial lead, 10 kA, 700 V115510+$1.231250+$1.1674100+$1.1218300+$1.0944500+$1.06701000+$1.03972500+$0.99865000+$0.9895
-
Category: surge protectionDescription: Bourns GDT Surge discharge device, 2015 series 2015 series 2-electrode gas discharge tube (GDT), adopts innovative flat packaging design to provide volume saving design, used for high-density, space limited printed circuit board applications, and provides horizontal and vertical surface mounting models, as well as lead free design, used for ink cartridge or clip installation applications. The 2015 series is ITU K.12 Class II equipment, rated at 5 kA for 8/20 μ s waveform, compact and space saving design, sturdy surge current rating, stable performance throughout the life cycle, low leakage and insertion loss, regardless of voltage, capacitor constant DC breakdown voltage range of 90 to 600 V. Applications include: telecommunications CPE; Industrial communication; Surge protection equipment and high-density printed circuit board components # # Switching spark gap (GDT) Switching spark gap is specifically designed for voltage controlled switching in capacitive discharge circuits that require high energy, low loss, and fast switching. These products are particularly suitable for applications that use transformers to obtain pulses of ultra-high voltage levels of thousands of volts through capacitive discharge. Can be used for gas heating and gas equipment in the construction and automotive fields, with xenon discharge lamp protection.500310+$1.063850+$1.0086100+$0.9692300+$0.9456500+$0.92201000+$0.89832500+$0.86295000+$0.8550
-
Category: surge protectionDescription: BOURNS 2035-23-SM-RPLF Gas Discharge Tube (GDT), precise, 2035 xx SM series, 230 V, 2-terminal SMD, 10 kA, 600 V99205+$1.358125+$1.257550+$1.1871100+$1.1569500+$1.13682500+$1.11165000+$1.101610000+$1.0865
-
Category: surge protectionDescription: Bourns 1800 Series signal and data line protection equipment Bourns 1800 series signal and data line protection equipment (SPD) has low peak clamping voltage even in severe current surges, and can repeatedly prevent high surge currents within rated limits. The 1800 series SPD can be easily installed and grounded on flat surfaces or DIN-1 (TS-32) or DIN-3 (TS-35) rail cable shields can pass through, and can be grounded or arc grounded. They have anti vibration screw clamp terminals and flame-retardant epoxy resin filled enclosures. Applications include: computers, data communication, instruments, broadcasting, and industrial control. Surge protection equipment, SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or other factors. Caused by lightning activity nearby. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.34261+$1248.740910+$1237.388725+$1231.712650+$1226.0365100+$1220.3604150+$1214.6843250+$1209.0082500+$1203.3321
-
Category: surge protectionDescription: Bourns 1800 Series signal and data line protection equipment Bourns 1800 series signal and data line protection equipment (SPD) has low peak clamping voltage even in severe current surges, and can repeatedly prevent high surge currents within rated limits. The 1800 series SPD can be easily installed and grounded on flat surfaces or DIN-1 (TS-32) or DIN-3 (TS-35) rail cable shields can pass through, and can be grounded or arc grounded. They have anti vibration screw clamp terminals and flame-retardant epoxy resin filled enclosures. Applications include: computers, data communication, instruments, broadcasting, and industrial control. Surge protection equipment, SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or other factors. Caused by lightning activity nearby. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.99681+$1214.171210+$1203.133325+$1197.614350+$1192.0954100+$1186.5764150+$1181.0574250+$1175.5385500+$1170.0195
-
Category: surge protectionDescription: Bourns 1800 Series signal and data line protection equipment Bourns 1800 series signal and data line protection equipment (SPD) has low peak clamping voltage even in severe current surges, and can repeatedly prevent high surge currents within rated limits. The 1800 series SPD can be easily installed and grounded on flat surfaces or DIN-1 (TS-32) or DIN-3 (TS-35) rail cable shields can pass through, and can be grounded or arc grounded. They have anti vibration screw clamp terminals and flame-retardant epoxy resin filled enclosures. Applications include: computers, data communication, instruments, broadcasting, and industrial control. Surge protection equipment, SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or other factors. Caused by lightning activity nearby. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.21411+$1194.536210+$1183.676825+$1178.247150+$1172.8174100+$1167.3877150+$1161.9579250+$1156.5282500+$1151.0985
-
Category: surge protectionDescription: 2095 Series gas discharge tubes, 8kA/2A axial lead type equipment with high voltage range and high insulation resistance applications including telecommunications, industrial, and consumer electronics products # # Transient voltage suppressors (inflatable)680310+$6.1848100+$5.8756500+$5.66941000+$5.65912000+$5.61795000+$5.56637500+$5.525110000+$5.5045
-
Category: surge protectionDescription: 2093 Series of gas discharge tubes, 5kA/3A surface mounted equipment with high voltage range and high insulation resistance applications including telecommunications, industrial, and consumer electronics products # # Transient voltage suppressors (inflatable)27955+$5.090925+$4.713850+$4.4498100+$4.3367500+$4.26122500+$4.16705000+$4.129210000+$4.0727
-
Category: surge protectionDescription: 2063 Series gas discharge tube, 100kA/60A axial no wire design, high power processing, low capacitance and low leakage application for telecommunications and industrial electronic products # # Transient voltage suppressor (inflatable)93361+$69.125410+$66.1199100+$65.5789250+$65.1582500+$64.49701000+$64.19642500+$63.77565000+$63.4150
-
Category: surge protectionDescription: BOURNS 2056-35-B2LF Gas Discharge Tube (GDT), Light Duty, 2056 series, 350 V, 3 terminal through holes, 5 kA, 750 V81775+$2.328825+$2.156350+$2.0355100+$1.9838500+$1.94932500+$1.90615000+$1.888910000+$1.8630
-
Category: surge protectionDescription: 2061 Series gas discharge tube, 60kA/40A axial no wire design, high power processing, low capacitance and low leakage applications for telecommunications and industrial electronic products # # Transient voltage suppressor (inflatable)59891+$63.391510+$60.6353100+$60.1392250+$59.7533500+$59.14701000+$58.87142500+$58.48555000+$58.1548
-
Category: surge protectionDescription: 2056 Series gas discharge tube, 5kA/5A small load, 3-electrode radial design with low capacitance and insertion loss, applied in telecommunications, industrial, and consumer electronics products # # # Transient voltage suppressor (inflatable)56435+$2.319325+$2.147550+$2.0272100+$1.9757500+$1.94132500+$1.89845000+$1.881210000+$1.8554
-
Category: surge protectionDescription: BOURNS 2057-23-BLF Gas Discharge Tube (GDT), Light Duty, 2057 Series, 230 V, Axial Lead, 5 kA, 700 V667310+$0.962650+$0.9126100+$0.8770300+$0.8556500+$0.83421000+$0.81282500+$0.78075000+$0.7736
-
Category: surge protectionDescription: Miniature SMD Gas Discharge Tube -2051 Series Bourns ® The 2051 series miniature gas discharge tube (GDT) is extremely compact in size (2.7 x 3.2 x 4.5 mm) and is a powerful overvoltage protection product. The 2051 series GDT is specifically designed to meet the circuit board level protection requirements of telecommunications and industrial communication equipment with space limitations, suitable for PCI cards, MDC modems, splitters, and CPE applications. In addition, the 2051 series GDT has low capacitance, making it ideal for high-speed/high bandwidth applications. ###Main features: - Small structure, low capacitance, stable performance throughout the lifecycle, high insulation resistance, UL certification # # # Applications include: - MDC/PCI modems, splitters, telecommunications CPE data communication # # # Transient voltage suppressors (inflatable)314410+$0.992350+$0.9408100+$0.9041300+$0.8820500+$0.86001000+$0.83792500+$0.80485000+$0.7975
-
Category: surge protectionDescription: BOURNS 2045-30-BT1LF Gas Discharge Tube (GDT), 2-Electrode, 2045 Series, 300 V, Axial Lead, 10 kA, 900 V939710+$1.297450+$1.2301100+$1.1820300+$1.1532500+$1.12441000+$1.09552500+$1.05235000+$1.0427
-
Category: surge protectionDescription: BOURNS 2045-25-BLF Gas Discharge Tube (GDT), 2-Electrode, 2045 series, 250 V, axial lead, 10 kA, 700 V282310+$1.238050+$1.1738100+$1.1279300+$1.1004500+$1.07291000+$1.04542500+$1.00415000+$0.9949
-
Category: surge protectionDescription: BOURNS 2035-23-BLF gas discharge tube35275+$1.414825+$1.310050+$1.2366100+$1.2052500+$1.18422500+$1.15805000+$1.147610000+$1.1318
-
Category: surge protectionDescription: Surge Arrestor 3-Electrode Gas Discharge Tube 300VDC 10kA SMD T/R45905+$3.626125+$3.357550+$3.1695100+$3.0889500+$3.03522500+$2.96805000+$2.941210000+$2.9009
-
Category: surge protectionDescription: MINI GAS DISCHARGE TUBE,2Pole,SMD,420V,T/R,HAZMAT49325+$1.356825+$1.256350+$1.1859100+$1.1558500+$1.13572500+$1.11055000+$1.100510000+$1.0854
